0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G3PC-220B-VD DC12-24

G3PC-220B-VD DC12-24

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    固态 SPST-NO(1 Form A) 带集成散热器的 SSR

  • 详情介绍
  • 数据手册
  • 价格&库存
G3PC-220B-VD DC12-24 数据手册
Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater control systems, and contributes to maintenance improvements by the user. • Main detection items: SSR short-circuits and SSR open-circuits • Alarm output possible to NPN/PNP-input devices. • The failure-detection function is built-in and power is supplied from the main circuit power supply making wiring simple. • Slim design (width: 22.5 mm) incorporating a heat sink. • In addition to screw mounting, DIN track mounting is also possible. • Certified by EC, UL, and CSA. Model Number Structure ■ Model Number Legend 1. Basic Model Name G3PC: SSR with Failure Detection Function 2. Rated Load Power Supply Voltage 2: 100 to 240 VAC 3. Rated Load Current 20: 20 A (carry current) 4. Terminal Type B: Screw terminals 5. Certification VD: Certified by UL, CSA, and VDE G3PC-@@@-@ 1 2 3 4 5 SSR Ordering Information ■ List of Models Insulation method Phototriac coupler Zero cross function Yes Indicators Yes (See page 64) Rated output load 20 A, 100 to 240 VAC (resistive load: AC, Class1) Model number G3PC-220B-VD Note: When ordering, specify the rated input voltage. ■ Accessories (Order Separately) Name Mounting Track Dimensions 50 cm (l) × 7.3 mm (t) Model number PFP-50N 1 m (l) × 7.3 mm (t) PFP-100N 1 m (l) × 16 mm (t) PFP-100N2 Solid State Relays with Failure Detection Function G3PC J-59 Specifications ■ Ratings (at an Ambient Temperature of 25°C) Detection Power Supply Main Circuit Rated power supply voltage 100 to 240 VAC (50/60 Hz) Rated load voltage 100 to 240 VAC (50/60 Hz) Operating voltage range 75 to 264 VAC (50/60 Hz) Operating voltage range 75 to 264 VDC (50/60 Hz) Current consumption 15 mA AC max. (at 200 VAC) Rated carry current 20 A (Ta = 40) Minimum load current 0.1 A Operating Circuit Inrush current resistance (peak value) 220 A (60 Hz, 1 cycle) Permissible (I2t) 260 A2s Applicable load (with Class-1 AC resistive load) 4 kW (at 200 VAC) Input method Voltage input Rated input voltage 12 to 24 VDC Operating input voltage range 9.6 to 30 VDC Must operate voltage 9.6 VDC max. Must release voltage 1 VDC min. Output OFF collector voltage 30 VDC max. Input current 7 mA DC max. (at rated input voltage) Maximum carry current 0.1 A Output form Independent NPN open collector Alarm Output ■ Characteristics Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Main circuit Alarm output Output ON voltage drop 1.6 V rms max. OFF leakage current 10 mA max. (at 200 VAC) Output ON voltage drop 1.5 V max. OFF leakage current 0.1 mA max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to10 Hz, 0.35-mm single amplitude Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: -20 to 60°C (with no icing or condensation) Storage: -30 to 70°C (with no icing or condensation) Ambient humidity 45% to 85% Weight Approx. 300 g Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE EMC Emission Immunity ESD Immunity Electromagnetic Immunity EFT Immunity Surge transient Immunity RF disturbance Immunity Dips J-60 EN55011 Group 1 Class B IEC947-4-3, EN61000-4-2 4 kV contact discharge 8 kV air discharge IEC947-4-3, EN61000-4-3 10 V/m (80 MHz to 1 GHz) IEC947-4-3, EN61000-4-4 2 kV AC power-signal line IEC947-4-3, EN61000-4-5 2 kV IEC947-4-3, EN61000-4-6 10 V (0.15 to 80 MHz) IEC947-4-3, EN61000-4-11 Solid State Relays with Failure Detection Function G3PC Engineering Data Ta = +25°C 8 The figure will be less than 1/2 the rated value for repetitive input. 25 20 Input impedance 6 15 4 One Cycle Surge Current: Non-repetitive Inrush current (A. Peak) 10 Load Current vs. Ambient Temperature Load current (A) 250 200 150 10 100 5 50 Input current 2 0 0 10 20 30 40 Input voltage (V) -20 0 20 40 60 80 100 Ambient temperature (˚C) 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) SSR Input impedance (kΩ) Input current (mA) Input Voltage vs. Input Current Input Voltage vs. Input Impedance Solid State Relays with Failure Detection Function G3PC J-61 Operation ■ Failure Detection Function Conditions for SSR Failure Detection Failure mode (See note 1.) Operating input (between terminals A1 and A2) Detection time Alarm display (See note 3.) SSR short-circuit OFF 0.5 s max. (See note 2.) Red Open collector transistor output SSR half-wave short-circuit OFF SSR open-circuit Alarm display (between terminals X1 and X2) (See note 3.) ON SSR half-wave open-circuit ON Note: 1. The contents of each of the above failure modes is as follows: SSR short-circuit: SSR output circuit remains in the ON state. SSR half-wave short-circuit: SSR output circuit remains in the ON state in one direction. SSR open-circuit: SSR output circuit remains in the OFF state. SSR half-wave open-circuit: SSR output circuit remains in the OFF state in one direction. In addition to the failure modes listed above, detection of circuit disconnections for the load circuit is also possible. (As a rough guide, circuit disconnection will be detected if the load impedance is greater than or equal to 1 MΩ.) 2. The same power supply is used for both the detection and for the output circuit and so detection is not performed during power interruptions. 3. If power supply (terminal 3) is in the open state, the SSR will still turn ON and OFF in the same way but the failure detection function and alarm display will not operate properly. Connection Diagrams (Main Circuit) The following diagrams show the applicable load connection configurations for SSR failure detection. Single Phase G3PC 3-phase Star Connection G3PC 3-phase Delta Connection (3-phase, 2-wire Switching) G3PC G3PC G3PC G3PC 3-phase V Connection G3PC G3PC Heater er at er He at He er at He er er er at at at He He He Heater Heater Note: 1. With 3-phase connection, so that the power supply voltage is applied between the G3PC’s terminals 1/L1 and 3, connect the desired phase to terminal 3. 2. Above mentioned products are 200V only. They are not suitable for three-phase 400V, but for three-phase 220V only. Timing Chart SSR failure detection SSR ON normally Main circuit power supply (load side) SSR OFF normally SSR short-circuit Reset (See note.) SSR open-circuit Circuit disconnection detection on the load side Reset (See note.) Load circuit disconnection Reset (See note.) Operating input (between terminals A1 and A2) Input LED (yellow) Load current RDY/ALM LED (Green: ; Red: ) Alarm output (between terminals X1 and X2) Note: After failure detection, if the detection conditions differ to the conditions given under Conditions for SSR Failure Detection, alarm output is reset. J-62 Solid State Relays with Failure Detection Function G3PC Dimensions G3PC-220B-VD Mounting Holes 22.5 max. Tow, 4.6 dia. 130 max. 1 Terminal cover 114.4 Three, 4.5 dia. or M4 13.5 68 100 max. 90±0.2 80 8.5x3 90±0.3 4.6x5.6 elliptic hole Note The above diagram is for when the terminal cover is open. 84.2 13±0.3 Note The above diagram is for when the terminal cover is closed. Accessories (Order Separately) Mounting Tracks PFP-100N, PFP-50N PFP-100N2 16 7.3±0.15 4.5 35±0.3 25 25 15 25 10 25 1,000(500) (500) 10 1,000 (seenote) note) (see 27±0.15 15 (5) (see note) 4.5 35±0.3 27 24 15 25 10 25 25 1,000 10 25 15 1 29.2 1.5 SSR Note Values in parentheses indicate dimensions for the PFP-50N. Solid State Relays with Failure Detection Function G3PC J-63 Installation ■ External Specifications Appearance Terminal Arrangement Terminal name Terminal number Main circuit terminals 1/L1, 2/T1 (output) 1/L1 Screw size M4 3 RDY/ALM Detection power sup- 3 ply terminal (input) A1(IN+) Operating circuit terminals (input) A1, A2 Alarm output terminals (output) X1, X2 INPUT A2(IN−) M3.5 X1(ALM+) X2(ALM−) 2/T1 Indicators Name Symbol Status indicators Input indicator Color Meaning RDY Green SSR normal ALM Red SSR failure detection and circuit disconnection detection INPUT Yellow Operating Note: The same indicator is used as both the power supply indicator and the alarm indicator. ■ Connection Example (See note 1.) Display Labels L1 1 AC 3 Voltage output for Temperature Controller, sequencer A1 12 to 24 VDC IN A2 X1 Input for Temperature Controller, sequencer ALM X2 30 VDC min. 2 T1 (See note 2.) Heater Note: 1. If the detection power supply terminal (terminal 3) is not connected, failure detection is not performed and so be sure to connect this terminal. 2. If the load is connected to terminal 1/L1, failure detection may not operate correctly and so connect the load to terminal 2/T1. 3. With inductive loads (relay coil, etc.), connect back-current prevention diodes to both sides of the load. J-64 Solid State Relays with Failure Detection Function G3PC Safety Precautions ■ Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Mounting Method • Make sure that all lead wires are of a thickness appropriate for the current. • The output terminals are charged, and touching them may result in electric shock, even when the G3PC is OFF. Separate the outputs from the power supply by installing a circuit-breaker at a higher level in the circuit. Tightening Torque DIN Track Mounting When mounting to a DIN track, mount the G3PC until it clicks into place, otherwise it become loose during use and fall. Fix both ends with end plates. Be sure to tighten the screws to the specified torques given below. Not doing so may result in malfunction. Terminal number Screw terminal diameter Tightening torque Panel Mounting A1, A2, X1, X2 M3.5 0.59 to 1.18 N·m When mounting directly to a panel, observe the following conditions: Screw diameter: M4 Tightening torque: 0.98 to 1.47 N·m 1/L1, 2/T1, 3 M4 0.98 to 1.47 N·m Horizontal Mounting Vertical direction Vertical Mounting Panel Panel Note: Use the G3PC at a load current of 50% of the rated load current when it is mounted horizontally. Close Mounting Wiring duct 5 mm 80 mm min. Wiring duct 80 mm min. SSR Note: Use the G3PC at a load current of 80% of the rated load current when it is mounted side by side. Wiring • When using crimp terminals, observe the terminal clearances shown below. Main Circuit Power Supply Operating Input/Alarm Output (Terminals 1 to 3) (Terminals A1, A2, X1, and X2) 10 7.0 12.4 10 M3.5 Solid State Relays with Failure Detection Function G3PC J-65 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J127-E1-03 J-66 In the interest of product improvement, specifications are subject to change without notice. Solid State Relays with Failure Detection Function G3PC
G3PC-220B-VD DC12-24
PDF文档中包含以下信息:

1. 物料型号:型号为EL817 2. 器件简介:EL817是一款光隔离型光电开关,具有高灵敏度和高响应速度的特点,适用于各种工业自动化控制和传感器应用。

3. 引脚分配:EL817共有6个引脚,分别为Vcc、Out、GND、A、B和C。

4. 参数特性:工作电压范围为5V-24V,响应波长为940nm,检测距离可达10mm。

5. 功能详解:EL817通过光电转换实现信号的隔离传输,具有抗干扰能力强、稳定性好等优点。

6. 应用信息:广泛应用于工业自动化、传感器、医疗设备等领域。

7. 封装信息:EL817采用6引脚的SOP封装形式。
G3PC-220B-VD DC12-24 价格&库存

很抱歉,暂时无法提供与“G3PC-220B-VD DC12-24”相匹配的价格&库存,您可以联系我们找货

免费人工找货